Thermocouples of IEC 584-3
a) Functionality / Norms
One connect 2 metals with different Thermoelectric strength to one thermo-pair so, an EMK develops at the free ends, their height isdependent on the difference of that Thermostrengths |
|
One gives the different thermo-pairs in the reference tables after IEC 584-3 Part 1 at, for example type K, J, N, S, R, B, T, E. The limit-deviations become in the Part 2 divided after tolerance-classes 1, 2 and 3 and document. The Part 3 treats that Extension – and Compensating leds; here the colorcode is for the respective thermocouples - type and the tolerance-class deposits. |
Limit deviation – tolerance-class for thermo-pair
(comparison-put-temperature 0 °C)
Type- thermo-pair +/- |
Class 1
|
Class 2
|
Class 3
|
K - NiCr / Ni
|
1,5 ° C or 0,4 % x t
- 40 ° C .......... +1000 °C
|
2,5 °C or 0,75 % x t
-40 °C .......+ 1200 °C
|
2,5 °C or 1,5 % x t
-200 °C ......... + 40 °C
|
J - Fe / CuNi
|
1,5 ° C or 0,4 % x t
- 40 ° C ....... +750 °C
|
2,5 °C or 0,75 % x t
-40 °C .........+ 750 °C
|
-
|
N - Nicrosil / Nisil
|
1,5 ° C or 0,4 % x t
- 40 °C .......+1000 °C
|
2,5 °C or 0,75% x t
-40 °C .........1200 ° C
|
2,5 °C or 1,5% x t
-200 °C.......... +40 °C
|
S - Pt10%Rh / Pt
R - Pt 13%Rh / Pt
|
1 ° C or
1+(t - 1100) x 0,003 °C
0 °C ......... + 1600 °C
|
1,5 °C or 0,25 % x t
0 °C ........... + 1600 ° C
|
-
-
|
B - Pt30% Rh / Pt6%Rh
|
-
|
0,25% x t
600 °C ......... 1700 °C
|
4 °C or 0,5 % x t
+600 °C ....... + 1700 °C
|
T - Cu/CuNi
|
0,5 °C or 0,4% x t
- 40 °C........ + 350 °C
|
1 °C or 0,75 % x t
- 40 °C .......... + 350 °C
|
1 °C or 1,5% x t
-200 °C ........... + 40 °C
|
E - NiCr/ CuNi
|
1,5 ° C or 0,4 % x t
- 40 ° C ........ + 800 °C
|
2,5 °C or 0,75% x t
-40 °C .......... + 900 °C
|
2,5 °C or 1,5 % x t
-200 °C ....... + 40 °C
|
For border-deviation (+/-) is valid the bigger value in each case and for the delivery-condition of the thermocouples. / t = | t |
|