Extension – and Compensating cable

Extension- and compensating cable are affordable, isolated extension-couples of the thermo-element in the principle – transition to the measuring instrument entrance. Extension-cable (X) are from Original-Thermomaterial and are to be received in class 1 as well as in class 2. Compensating-cable (C) are from an alloy of different materials, which behaves similarly, like thermo-material, but only as class 2 defined is (sees table below). 

Subsequently the table after the norm IEC 584-3 for the color-code and the class-precision of that extension- or compensating cable.

Colors, tolerances and temperature-areas, international valid table of color codes                      

Type Color code Class 1 Class 2 Application temperature Measuring temperature
KX KCA KCB Farbcode ± 1,5 °C - - ± 2,5 °C ± 2,5 °C ± 2,5 °C -25 °C .......+200 °C 0 °C ...... + 150 °C 0 °C .......+ 100 °C 900 °C
JX Farbcode ± 1,5 °C ± 2,5 °C -25 °C .......+200 °C 500 °C
NX NC Farbcode ± 1,5 °C - ± 2,5 °C ± 2,5 °C -25 °C .......+200 °C 0 °C ...... + 150 °C 900 °C
SCA SCB RCA RCB Farbcode - - - - ± 2,5 °C ± 5,0 °C ± 2,5 °C ± 5,0 °C 0 °C .........+ 100 °C 0 °C .........+ 200 °C 0 °C .........+ 100 °C 0 °C .........+ 200 °C 1000 °C
TX Farbcode ± 0,5 °C ± 1,0 °C -25 °C .........+ 100 °C 300 °C
EX Farbcode ± 1,5 °C ± 2,5 °C -25 °C .........+ 200 °C 500 °C
B Farbcode - ± 3,5 °C 0 °C .........100 °C 1400 °C
L Farbcode - ± 3 °C nach DIN 43 714 (old norm) ± 3 °C nach DIN 43 714 (old norm) ± 3 °C nach DIN 43 714 (old norm)

The table shows it to limiting-deviation maximum for Extension- and Compensating–cable , if they are driven within the application-temperature-area, the limit-values are applied to the stated measuring temperatures (last columns).